Fire door checks
Gaps, seals, hinges, closers and glazing checked and reported, with remedials priced up front.
Compliance · doors, signage & training
A fire door only works if the whole assembly is right. We verify fire doors against BS 476-22 or BS EN 1634-1, and provide fire safety signage and training to match.
Takes 60 seconds. Free survey, free quote, no obligation.
Thanks, we'll call you within one working day to confirm your visit.
Need us sooner? Call 020 3837 0778Mon to Fri 9am–7pm · Sat 10am–3pm
BAFEFire Safety Register 303184
FikeApproved installer
C-TECCertified engineers
Gas SafeGroup registration
NICEICGroup registration
ibRegistered member
A fire door only works if it closes, a sign only works if it is where people look, and a plan only works if staff have practised it.
Gaps, seals, hinges, closers and glazing checked and reported, with remedials priced up front.
Escape routes, final exits and equipment signed to the standard, not with whatever was in the van.
Basic fire awareness and extinguisher use, so the people in the building know what to do first.
Checks and training logged, so the evidence exists when an inspector or insurer asks.
A fire door is a system, not just a heavy door. It only holds back fire and smoke for its rated period if every part is correct: the leaf, the frame, the intumescent seals, the hinges, the closer, and the gaps around the edges. The most common problems we find are worn seals, damaged closers, excessive gaps and doors propped open. We verify the whole assembly against BS 476-22 or BS EN 1634-1.
Direct answer: a fire door works only when the complete assembly is right, the leaf, frame, seals, hinges, closer and edge gaps together. Verifying it against BS 476-22 or BS EN 1634-1 confirms it will resist fire and smoke for its rated period.
Frequency comes from your fire risk assessment and the building type. Government guidance points to quarterly checks of fire doors in the common parts of higher-risk residential buildings, and many managers inspect commercial fire doors at least every six months. We can carry out the inspections and keep the records with the rest of your compliance paperwork.
Both jobs get called the same thing on the invoice. This is what actually differs.
Four steps, the price agreed in writing before anyone starts, and one accredited team from survey to certificate.
We inspect doors, signage and what your staff have actually been trained on.
A clear list of what fails and what it costs to put right, with no obligation.
Doors adjusted or replaced, signage installed, training delivered on site.
Reports and training records handed over for your fire safety file.
A cross-section of the offices, HMOs and blocks we look after across London.
The old panel kept throwing faults and our previous company never turned up. Flame Shield took it over, cleared the faults in one visit, and we get a certificate every service now.
Fire alarm and emergency lighting across a three-storey office, on a tight deadline. Clean job, tidy cabling, and the BS 5839 side explained in plain English.
As a landlord with two HMOs I just want it compliant and documented. Their engineer talked me through what the regs need and emailed the certificates the same week.
Fire doors on escape routes and in common areas should be checked regularly. Government guidance points to quarterly checks of fire doors in the common parts of higher-risk residential buildings, and many managers inspect commercial fire doors at least every six months. Your fire risk assessment sets the frequency for your building.
A fire door only performs if the whole assembly is right: the door leaf, frame, intumescent seals, hinges, closer, and the gaps around the edges. We verify fire doors against BS 476-22 or BS EN 1634-1 and check that every component and the installation itself will hold back fire and smoke for the rated period.
Yes. Alongside fire doors we supply and position fire safety signage, and we provide fire safety training covering extinguisher use, evacuation procedures, regular checks and general awareness. It is a practical package for keeping a building and its people compliant.
We verify fire doors against the relevant standard and provide a fire door certificate recording the inspection and its findings. Where doors or components fall short, we set out what needs putting right so the assembly performs as intended.
The legal starting point under the Fire Safety Order 2005, by a team that can also fix what it finds.
Fire risk assessment
Installation, testing and certification to BS 5266-1 so escape routes stay lit when the power fails.
Emergency lighting
Supply, servicing and certification of water, foam, CO2 and powder extinguishers to BS 5306.
Fire extinguishersFree survey · No obligation
Verify your fire doors against the standard, and sort signage and training in the same visit. Book online or call us.
We would like to set Google Analytics cookies to see how the site is used, so we can improve it. We only set them if you accept. Nothing is loaded until you choose, and refusing changes nothing about how the site works.